            Automatic External Defibrillator – AED7000

            Specifications:

            • Three-step defibrillation process
            • Tow-button operation
            • Extensive voice and visual prompts for the operator
            • Biphasic energy output
            • lock-out protection to prevent inadvertent defibrillation
            Download Catalog

            Defibrillator

            CategorySpecification
            outputBiphasic Truncated exponential
            Energy sequence
            Charge Time
            150, 150, 200j
            8 sec. to 150j
            10 sec. to 200j (New battery)
            analysis Time9 sec.
            The maximum time from the initiation of rhythm analysis to readiness for discharge with a new batteryless than 30seconds
            The maximum time from the initiation of rhythm analysis to readiness for discharge after 6 shocks. less than 35seconds
            The maximum time from the initiation switching power on to readiness for discharge.
            audible prompts
            less than 25 seconds
            20audible prompts
            visual promptsLED prompts
            controlsTwo buttond – On/Off,Shock
            Output Energy Accuracy±15% intoany impedance from 25 to 175
            Out disabled when the patient impedance is outsidw 20 to 20
            Battery
            Part No
            Non-rechargeable
            CR1234A-4×2
            12V d.c. 3.0Ah
            Capacity100 disccharges at200 joules or 120 discharges at150 joules
            Shelf Life (25 C±15 C)10 years (5 years storage+5 years standby) 5 years standby (after installation)
            Physical
            Dimensions
            Weight
            Operating Temperature
            Operating humidity
            303*216*89mm
            2.0 kg
            0 Cto 40 C
            Relative humidity between 30% and 95% (non- condensing)
            Storage Temperature
            (without battery)
            -20C to 55C
            Storage Humiditry
            (without battery)
            Up 93% (non-condensing)

            Related posts

            October 4, 2021

            Defibrillator Monitor – DM7000


            Read more

            BİOSTAR HEALTHCARE TIBBİ ÜRÜNLER SAN.TİC.LTD.ŞTİ.

            GÖZTEPE MAH. BATIŞEHİR CAD. BATIŞEHİR K BLOK 2 /1 2B1 BAĞCILAR-İSTANBUL

            LINKS


            Home
            Products
            About us
            Contact us

            PHONE


            +90 212 392 92 75


            If you have a question,
            please contact at [email protected]

            © 2021 Biostar Medikal | All Rights Reserved | Powered by Speed of Light
              EN
                        Not found text See all results
                        • EN
                        • TR