            Defibrillator Monitor – DM7000

            Specifications:
            Display:
            Display Type: 7 inch high resolution LCD display Sweep Speed: 25mm/sec Information: HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.
            Defibrillator:

            Waveform: Biphasic 

            Charge Time: Less than 7 seconds with a new fully charged battery. Energy Display: Monitor display indicates both selected and delivered energy. Charge Prompt Type: Voice and visual prompts. Electrode Impedance Measurement Range: 0–250 ohms.
            ECG Monitoring:
             Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles. Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V. ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor. Heart Rate: 20–300BPM. Heart Rate Alarm: On/Off displayed on monitor, user-selectable. Smart Alarms: Beeper/voice prompts indicate shockable rhythm. 
            SpO2 Module(Optional):
            Measurement Range: 30~100%, + 2% between 80%~90%, others 5% Alarm Range: User set high limit and low limit. Alarm Accuracy: + 10% within setting values. Alarm time Accuracy: Less than 12 sec.
            Recorder:
            Paper: 50mm thermal. Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay. Printing Method: High-resolution, thermal print head. Print-out Modes: Manual or automatic, user-configurable. On/Off Control: Front panel and paddle. Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or de fibrillatory discharge. 
            Battery:
            Type: Rechargeable, Ni-MH battery, 12V. Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. AED Mode AED Function: Auto analyze and charge X3 with programmable auto energy level selection, screen prompts, and voice prompts. Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms. Charge Control: Control on device front panel, press key on paddle. Prompts: Voice and visual prompts.
            Manual Mode:
            Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules. Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor

            Download Catalog

            Related posts

            October 8, 2021

            Stackable Syringe Pump SP1


            Read more
            October 7, 2021

            Automatic External Defibrillator – AED7000


            Read more
            October 6, 2021

            DUS60


            Read more

            BİOSTAR HEALTHCARE TIBBİ ÜRÜNLER SAN.TİC.LTD.ŞTİ.

            GÖZTEPE MAH. BATIŞEHİR CAD. BATIŞEHİR K BLOK 2 /1 2B1 BAĞCILAR-İSTANBUL

            LINKS


            Home
            Products
            About us
            Contact us

            PHONE


            +90 212 392 92 75


            If you have a question,
            please contact at [email protected]

            © 2021 Biostar Medikal | All Rights Reserved | Powered by Speed of Light
              EN
                        Not found text See all results
                        • EN
                        • TR